The PDUMNV20LX 1.9kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. Recommended for any IT or industrial application, it features 24 NEMA 5-15/20R outlets with included cord retention brackets to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L5-20P plug and 5-20P adapter connects the PDU to a compatible AC power source, generator or protected UPS.The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.A digital ammeter allows you to monitor the PDU's current level in real time to ensure it remains well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.Distributes Network-Grade Single-Phase Power- 1.9kW 120V 20A monitored PDU with single-phase input/output- NEMA L5-20P with 10 ft. cord connects to compatible AC power source- NEMA 5-20P adapter converts locking input plug to straight-blade plug- Firmware upgrades support future product enhancements24 Outlets Distribute AC Power- 24 NEMA 5-15/20R outlets- Cord retention bracket prevents cables from becoming accidentally disconnectedDigital Ammeter- Reports total connected equipment load- Supports IP-address self-ID- Rotates 180° for easy reading at either angleBuilt-In LX Platform Interface- Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities- No Java requiredBroad Communications Compatibility- Supports HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP- Supports automatic and manual assignment of IP addressEasy 0U Installation in EIA-Standard 19 in. Racks- Mounts vertically using included toolless buttons or rack-mounting brackets- Included PDUMVROTATEBRKT allows mounting with rear-facing outletsTAA-CompliantCompliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Eaton EATS120 power distribution unit (PDU) 10 AC outlet(s) 1U Black
Tripp Lite Basic Power Distribution Units / PDU systems offer reliable rackmount power distribution. Supplies equipment with continuous power from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 15A single phase 120V Basic Power Distribution Unit / PDU (Agency de-rated to 12A continuous)- 0U 36in / 91.4cm vertical rackmount format PDU installs using no rack spaces- 14 NEMA 5-15R outlets- Attached NEMA 5-15P 15A 120V input plug with 15ft / 4.5m line cord- 15A resettable circuit breaker- Switch-free design prevents accidental shutoff- Toolless mounting buttons enable simple installation in compatible equipment racks- Rear facing installation buttons can be relocated to the left or right surface of the PDU for rear, center or forward-facing outlet orientation in compatible racks- Included nut and bolt mounting brackets support installation in non button-mount compatible racks, wallmount and raceway applications
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. - Single phase 20A 120V Auto Transfer Switch / ATS PDU - Enables redundant A/B power option for single-corded network devices - Separate primary & secondary inputs connect to any two compatible power sources - 1U horizontal rackmount; 2 L5-20P / 5-20P inputs; 16 5-15/20R outlets - Individually switched outlets and Built-in network interface for remote control and monitoring; Two digit visual current meter - ATS / Switched PDU with attached L5-20P input power cord - Detachable C19 to NEMA L5-20P 12 ft/3.6m secondary input cord - Two NEMA L5-20R to NEMA 5-20P plug adapters - Installable 1U mounting brackets - User manual with warranty information - 120V 20A Power Distribution Unit (PDU) with Auto-Transfer Switch (ATS) and Switched outlets (Agency de-rated to 16A) - Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord - Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface - Digital display continuously reports total output power consumption in amps - 16 switched NEMA 5-15/20R outlets - 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth - Set of two 12 ft. / 3.6m NEMA L5-20P input cables with set of two 5-20P adapters support connection to separate PRIMARY and SECONDARY inputs - ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable - ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series) - Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported - On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source - Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds - DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols - Compatible with optional ENVIROSENSE temperature monitor - Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized - Front panel LEDs confirm power availability on both input lines
APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
208/230V Switched Power Distribution Unit / rack PDU (rPDU) with built-in web/network interface (12A 208V and 10A at 230V)C14 power inlet accepts a wide variety of worldwide input cord optionsIncludes 6.5 ft. / 2m C14 cable1U horizontal rackmount form factor8 switched C13 outletsSupports power-on, power-off or reboot of each outlet on a real-time or programmable basisEnables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outletsPre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsIP-based Auto Probe detects lost connectivity and restores service autonomouslyIn-rack environmental reporting with optional temperature, humidity and contact-closure sensor options10/100 Mbps auto-sensingIncluded cord retention brackets keep vital network equipment plugged in and continuously powered
Eaton EMI104-10 power distribution unit (PDU) 42 AC outlet(s) 38U-A Black
"- 4 outlets- 6 ft. cord- 7.38"" length- All metal housing- Lighted on/off switch with locking safety coverThe Waber-by-Tripp Lite UL603CB-6 Power Strip offers a convenient method of power distribution in workbench, wallmount or floor mount applications. Includes 4 NEMA 5-15R output receptacles with 1.25 inch center-to-center spacing, 6 foot AC line cord and keyhole mounting tabs for installation in a wide variety of applications. Corded, multi-outlet strip reduces cabling clutter and enables the connection of multiple electrical devices to a single AC wall socket. Unfiltered electrical pass-through makes UL603CB-6 ideal for distributing alternate waveform UPS or generator power. Features rugged all-metal housing, lighted power switch with transparent guard to prevent accidental shutoff, 15 amp resettable circuit breaker and attractive blue/gray color scheme."
The PDUMV40 provides an efficient and manageable power distribution solution for multiple servers with dual redundant power supplies, or any other application that requires numerous outlets, high capacity, and a compact form factor. Dual input current monitoring display shows AC power consumption for each independent circuit. Switchless design eliminates accidental shutoff of connected equipment. Unfiltered electrical pass-through without a power switch makes the PDUMV40 ideal for distributing alternate waveform UPS or generator power in rack enclosures, network closets, and more. Each of two independent circuits' supports 16 outlets and equipment loads up to 2,400 watts32 outlets and 4,800 watts total capacity without consuming additional rack space.- All-in-one Zero U form factor enables efficient, single-enclosure installations- Dual independent circuit design delivers high capacity across 32 outlets in minimal space- Input plugs, input power cords, breakers and outlets are color-coded to match each independent 20A circuit, allowing simplified cable management for multi-server configurations (each circuit is Agency de-rated to 16A continuous)- Dual digital current monitoring displays (1 for each circuit)- 10 ft. dual input power cords increase mounting flexibility; mounting hardware included- Combines the advantages of two separate high-current PDU's without the extra expense, increased space requirements and added management complexity- Includes two adapters that convert NEMA L5-20P input plugs to NEMA 5-20P. Twist-lock interface ensures secure connection- Switchless design prevents accidental shutdown of connected equipment- Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications
"APC AP9571A. Product color: Gray. Input connection type: NEMA L6-30P. Cable length: 144.1"" (3.66 m). AC input frequency: 60 Hz, Nominal output voltage: 208 V, Maximum total current draw per phase: 24 A. Dimensions (WxDxH): 17.5 x 3.03 x 1.73"" (445 x 77 x 44 mm), Weight: 5.62 lbs (2.55 kg)"
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA