APC Smart-UPS 2200VA RM 3U 120V/230V In 120V Out. Output power capacity: 2.2 kVA, Output power: 1600 W, Input frequency: 60 Hz. Typical backup time at full load: 6.8 min, Typical backup time at half load: 24.5 min, Battery recharge time: 3 h. Product color: Beige, Cable length: 72" (1.83 m). Package weight: 103.2 lbs (46.8 kg). Battery type: leakproof, Interface: DB-9/RS-232, Input connection type: NEMA 5-20P
APC Smart-UPS 1500VA. Output power capacity: 1.44 kVA, Output power: 980 W, Input frequency: 60 Hz. Typical backup time at full load: 6.7 min, Typical backup time at half load: 23.9 min, Replacement battery cartridge: RBC7. Product color: Black, Cable length: 72" (1.83 m). Weight: 53.1 lbs (24.1 kg), Package weight: 58.2 lbs (26.4 kg). Interface: DB-9/RS-232, Input connection type: NEMA 5-15P, Dimensions (WxDxH): 6.69 x 17.3 x 8.5" (170 x 439 x 216 mm)
The SMX1500SLT SmartPro® 230V 1.5kVA 900W Line-Interactive Sine Wave UPS provides battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. Ideal for backing up point-of-sale applications, VoIP systems and small business networks, the SMX1500SLT switches to battery mode in milliseconds to keep your connected equipment running long enough to save files and shut down safely with no data loss.Featuring eight C13 outlets and a C14 inlet that accepts a user-supplied AC power cord, the SMX1500SLT has an internal battery that provides 20 minutes of support at half load and eight minutes at full load. Front-panel LEDs indicate line power, voltage regulation, load level and battery status. An alarm sounds to indicate power failure or overload.Automatic voltage regulation (AVR) maintains selectable 220V, 230V or 240V nominal output over an input range of 174V–266V (220V), 182V–278V (230V) or 190V–290V (240V) without using battery power. EMI/RFI noise filtering improves your equipment’s performance and prevents damage. A 350-joule surge suppression rating protects your equipment from harmful power surges. With downloadable PowerAlert® software, the SMX1500SLT enables safe unattended system shutdown in case of a prolonged power failure. Adding an optional Network Managment Card permits remote management of the UPS.Protects Mission-Critical EquipmentProvides fully regulated sine wave AC output for point-of-sale applications, VoIP systems and small business networksAudible alarm signals loss of utility power or overload8 C13 outletsC14 inlet accepts user-supplied AC power cord with country-specific plug350-joule surge suppression ratingReliable Battery BackupSupports half load up to 20 min. and full load up to 8 min.Internal batteries designed for hot-swap field replacementCold-start capability enables turn-on in battery mode during blackoutsAutomatic Voltage Regulation (AVR)Maintains selectable nominal output without using battery powerCorrects brownouts and overvoltages from 174V–266V (220V), 182V–278V (230V) or 190V–290V (240V)EMI/RFI Line Noise FilteringRemoves electromagnetic and radio frequency interference that can disrupt or damage equipment’s performanceLED IndicatorsFront-panel LEDs indicate line power, voltage regulation, load level and battery statusNetwork Management CardsCompatible with UPS management card options WEBCARDLX, SNMPWEBCARD and RELAYIOCARDOptional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsCommunication PortsUSB & Serial ports enable data-saving unattended shutdown when used with PowerAlert software, available via FREE download from tripplite.eaton.com/products/power-alert Telephone/Network JacksProtect against power surges over telephone/DSL or network Ethernet lines
Tripp Lite SU16KRTHW 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.Tripp Lite SU16KRTHW 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configurationUnique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and underIncluded Parallel PDU with manual bypass switch enables hot-swap replacement power modules at any supported load levelHardwire input (3 wire) and hardwire output (3 wire) connectionsSupports North American (L1,L2,G) 208/240v hardwire input / output, plus International 230/220/240v (L,N,PE) hardwire input / outputOptional SU6000XFMR2U transformer offers 120v output in North American 208/240V (L1,L2,G) input configurationsMaintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominalSupports 50/60Hz operation for worldwide frequency compatibilityCompatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD (NOTE: Applications utilizing any supported network management card option, require the installation of two of the same model network card – install one card per included UPS power module)Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsExpandable runtime with optional external battery packsSome external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)Battery independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteriesIntelligent battery management system with temperature-compensated charging extends battery lifeHID-compliant USB interfaceUSB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralertOptional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required)Optional 2-9USTAND supports upright tower placement (2 required)Supports Emergency Power Off (EPO) via built-in interfaceFront panel LEDs and LCD readout with scroll controlsLED / LCD display panel rotates for viewing in rackmount or tower configurationsExternal battery packs are field replaceable and hot swappableFrequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Online, double-conversion Uninterruptible Power Supply (UPS) with Transformerless, IGBT technology maintains perfectly regulated output power by continuously converting raw AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Battery independent restart. Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs.- Tripp Lite SU3000RTXLCD3U 3000VA / 3kVA / 2700W on-line, double-conversion 3U rackmount UPS- Transformerless, IGBT technology- Selectable 100/110/120/127V output (120V factory preset)- NEMA L5-30P input, 4 NEMA 5-15/20R, 4 5-15R & 1 L5-30R outlets- Two switched 4-outlet load banks support remote reboot or programmable load shedding options- Supports 2% output voltage regulation and zero transfer time in double conversion mode- Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions- 11 minutes runtime at 50% load (1350W) and 4 minutes at 100% load (2700W) with internal batteries- BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs available (some configurations require Tripp Lite's External Battery Configuration Software)- LCD interface reports operating mode plus 9 selectable screens of UPS data (Load percentage, kW & kVA, Power factor, Input voltage & frequency, Output voltage & frequency, Battery voltage and charge percentage, Minutes runtime, Capacity remaining and Kw/hr. consumption)- LCD interface also supports 16 screens of UPS configuration and setup options- 4 post installation hardware included, Optional 2POSTRMKITHD enables 2 post rack installation- Single line TEL / Network surge suppression- Electronic bypass maintains utility output during a variety of UPS fault conditions- Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement- Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz- Built-in USB, RS-232, contact-closure and optional SNMPWEBCARD accessory monitoring options- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X- Included PowerAlert UPS monitoring software
3000VA / 3kVA / 2400 watt on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Attractive upright tower format. Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs. Full time sine wave 110/120V output with +/-2% voltage regulation. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 150V. Up to 97% efficiency in optional economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA L5-30R, NEMA 5-15/20R and NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces include USB port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two bank PDU switching supports automated load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs. Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. Field replaceable, hot swappable internal batteries and external battery packs. $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).- SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications- Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation- Economy mode is schedulable via PowerAlert UPS management software for daily or weekly hours of operation to enable precision output during peak operating hours and high efficiency, low BTU emission operation during off-peak times- Maintains continuous operation through blackouts, voltage fluctuations and surges- On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) with zero transfer time- Supports operation at 50/60Hz (auto-sensing)- Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types- Corrects line voltage conditions as low as 65V and as high as 150V to within 2% of selected nominal voltage- Standard internal battery set offers 14 minutes runtime at half load (1200W) and 5 minutes at full load (2400W)- Expandable battery runtime with optional BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US (multi-pack compatible) external battery packs- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions- Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot- HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP- UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control, remote reboot and UPS nominal voltage adjustment- Built-in Emergency Power Off (EPO) interface with cable- NEMA L5-30P input plug / NEMA 5-15R, 5-15/20R & L5-30R output receptacles- Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks- Front panel LEDs offer current monitoring and battery charge level information- Network grade AC, TEL/DSL or ethernet line surge suppression- Field replaceable, hot swappable internal batteries and external battery packs- $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA