Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.High frequency designReduces or eliminates bulky transformers resulting in lighter units for ease of handling.Auto recognition of external batteriesUPS recognizes when external battery packs are attached and automatically adjusts runtime.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Sequenced shutdown and restartConfigure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).InfraStruXure Central compatibleEnables centralized management via APC InfraStruXure® Central.Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Multiple switched outlet groupsMultiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.High online efficiencyReduces utlility costs, generates less heat.SmartSlotCustomize UPS capabilities with management cards.Cold-start capableProvides temporary battery power when the utility power is out.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Scalable runtimeAllows additional run time to be quickly added as needed.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.
APC Smart-UPS, Lithium-Ion, Short Depth 1000VA, 120V with SmartConnect Port and Network Management
Low operating and maintenance costs with proven reliability and intelligent battery management.Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.Save time with easy and convenient remote accessibility.Network manageable via serial, USB or optional Ethernet. Includes Powerchute Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.Peace of mind that comes with full equipment compatibility and reliability of a leaderProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.Avoids costly power problems by keeping your IT equipment and data protected and available.Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
"APC BK350. Output power capacity: 0.35 kVA, Output power: 210 W, Input frequency: 50/60 Hz. Typical backup time at full load: 4.7 min, Typical backup time at half load: 18.1 min, Battery recharge time: 8 h. Product color: Beige, Cable length: 70.9"" (1.8 m), Safety: UL/FCC/CE/C-Tick. Weight: 13.2 lbs (5.98 kg). Package weight: 14 lbs (6.36 kg)"
Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.High frequency designReduces or eliminates bulky transformers resulting in lighter units for ease of handling.Auto recognition of external batteriesUPS recognizes when external battery packs are attached and automatically adjusts runtime.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Outlet group controlTurn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).Load sheddingTurn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Multiple switched outlet groupsMultiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.Wide input voltage rangeDesigned for harsh electrical environments to save battery life.StruxureWare Central compatibleEnables centralized management via StruxureWare Central.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceHigh online efficiencyReduces utlility costs, generates less heat.LED IndicatorsProvide easy-to-read status of the unit and utility power conditions.Overload protectionSafeguards unit from damage by automatically turning it off in the event of a short circuit or overload.SmartSlotCustomize UPS capabilities with management cards.Cold-start capableProvides temporary battery power when the utility power is out.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedDisconnected battery notificationWarns when a battery is not available to provide backup power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltageregulation.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Audible alarmsProvides notification of changing utility power and UPS power conditionsUser-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)USB connectivityProvides management of the UPS via a USB port (not available on all models).Serial ConnectivityProvides management of the UPS via a serial port.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).Scalable runtimeAllows additional run time to be quickly added as needed.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Network manageableProvides remote power management of the UPS over the network.Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.Predicitive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.Sequenced network shutdown and rebootCustomize network shutdown and reboot sequence of connected servers and UPSs.
Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Disconnected battery notificationWarns when a battery is not available to provide backup power.Network manageableProvides remote management of the UPS over the network.Audible alarmsActively let you know if the unit is on battery, if the battery is low or if there is an overload condition.LED status indicatorsQuickly understand unit and power status with visual indicators.Serial ConnectivityProvides management of the UPS via a serial port.USB connectivityProvides management of the UPS via a USB port (not available on all models).Disconnected battery notificationWarns when a battery is not available to provide backup power.
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Battery replacement without toolsEnables fast battery replacement, lowering Mean Time to Repair (MTTR).Boost Automatic Voltage Regulation (AVR)Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.Building Wiring Fault IndicatorThis LED informs users of potentially dangerous wiring problems in the wall circuit.Dataline surge protectionProvides protection of connected equipment from power surges on the data lines.EMI and RFI noise filteringReduces line noise that can cause data loss and keyboard errors.ENERGY STAR for UPSEstablishes that the efficiency of the UPS is in the top 25% of the market as verified by third party testingHot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedLCD graphics displayText and mimic diagrams that display modes of operation, system parameters and alarms.
High density, double-conversion on-line power protection with scalable runtime.- Generator compatible- Cold-start capable- Power conditioning- Frequency and voltage regulation- 208/240V to 120V Step-Down Transformer- Resettable circuit breaker- Safety-agency approved- Network manageable- Low operating and maintenance costs with proven reliability and intelligent battery management- Avoids costly power problems by keeping your IT equipment and data protected and available- Peace of mind that comes with full equipment compatibility and reliability of a leader- Save time with easy and convenient remote accessibility
SmartSlotCustomize UPS capabilities with management cards.Cold-start capableProvides temporary battery power when the utility power is out.Serial ConnectivityUse any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.Resettable circuit breakersEnables a quick recovery from overload events.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedDisconnected battery notificationWarns when a battery is not available to provide backup power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Audible alarmsProvides notification of changing utility power and UPS conditions.Serial ConnectivityProvides management of the UPS via a serial port.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.Network manageableProvides remote management of the UPS over the network.Adjustable voltage sensitivityProvides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.LED status indicatorsQuickly understand unit and power status with visual indicators.
APC Smart-UPS SRT, Lithium-Ion, 3000VA 120V, with SmartConnect, with Network Management Card
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA