BP36V15-2U rack/tower external battery pack offers extended battery runtime when used in conjunction with expandable 36V rack-mount and tower UPS systems. Includes heavy-gauge cabling with high-current DC connector for safe, simple installation. Included mounting accessories support 2U rack-mount installation in 4-post racks. Options for 2-point front-rail mounting, 2-post center-mounting, wall-mount and upright tower installation available.Compatible with SMART1000RMXL2U, SMART1200XLHG, SMART1500RMXL2Ua, SMART1500XL, SMX1200XLHG, SMX1500XLRT2U and other UPS systems that specify the use of this battery pack.
Multi-Device Charging Station Accommodates up to 48 iPads and Other TabletsThe 120V CS48USB provides USB charging, device syncing, secure storage and cord management for as many as 48 iPad, Android, Surface, Kindle and other USB tablets, smartphones and devices. The connected devices’ chargers connect to the charging station’s 48 USB ports, which provide the fastest charging supported by each device up to 2.4A per port. Locking Steel Enclosure Keeps Valuable Equipment Safe and SecureConstructed from heavy-duty steel covered with a powder-coated finish, this tablet charging station provides safe, secure storage. Doors lock with the included keys to help prevent theft, damage and tampering. Flow-through ventilation helps protect against overheating, and the specially coated shelves help prevent device scratches and scuffs.Supports Convenient SyncingThe USB sync uplink port connects to a host computer for wired or wireless syncing. The CS48USB can sync and charge devices at the same time, up to 1.5A charging per port during wired syncing.Comes Fully Assembled for Immediate UseThe CS48USB ships fully assembled and supports mounting to a wall, desk, table, counter or floor. The front door opens 180 degrees to allow full access to the interior. Removable dividers accommodate thicker USB devices. A firmware upgrade port allows future updates. To move the charging station from room to room, you may convert it to a mobile cart using the optional CSHANDLEKIT accessory (sold separately). A detachable 10-foot (3.1-meter) power cord with NEMA 5-15P plug connects the charging station to an available AC outlet.
"Tripp Lite HCRK-54. Input voltage: 120 V, Output power: 350 W, Output voltage: 120 V. Product color: Black. Package width: 15.1"" (383.5 mm), Package depth: 17.9"" (454.7 mm), Package height: 19.4"" (492.8 mm). Master (outer) case width: 15.1"" (383.5 mm), Master (outer) case length: 17.9"" (454.7 mm), Master (outer) case height: 19.4"" (492.8 mm)"
"Tripp Lite MRV2012UL. Output power: 2000 W, Output voltage: 120 V, Country of origin: China. Product color: Black. Width: 10.5"" (266.7 mm), Depth: 17.5"" (444.5 mm), Height: 8"" (203.2 mm). Package width: 21.2"" (538.5 mm), Package depth: 13.5"" (342.9 mm), Package height: 12.1"" (307.3 mm). Master (outer) case width: 21.2"" (538.5 mm), Master (outer) case length: 13.5"" (342.9 mm), Master (outer) case height: 12.1"" (307.3 mm)"
11kW 3 phase 400V input, 230V output Monitored Power Distribution Unit (PDU) with built-in web/network interfaceAttached IEC-309 Red 16A (3P+N+E) 400V 3 phase input plug with 3m cord0U / 178cm vertical form factor supports installation in 2 or 4 post equipment racks36 total 230V outlets (30 C13, 6 C19) arranged in three single phase output load banksLighted display with scroll-button reports power consumption in amps for all 3 loading banks, IP-address self-identification and 180 degree display rotation for overhead or raised floor power feeds.Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading per-phase via network or secure web browser interface with options for user specified alarm and notification thresholdsSupports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensorsDHCP/Manual configuration support10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networksReal-time clock backup maintains the time of day and date even if the PDU is not powered onTiered access privileges allow an administrator and a guest to login via web browser for monitoringAlert notifications via email or SNMP traps offer immediate event notificationFirmware upgrade ability supports future product enhancements.Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocolsFully compatible with FREE PowerAlert Network Management System / NMS SoftwareIncluded cord retention brackets keep vital network equipment plugged in and continuously poweredToolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)
Tripp Lite Metered PDU / Power Distribution Units offer real-time local reporting of load level in amps via built-in digital meter. Enables visual current monitoring of PDU output current to prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.
Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.- 20A 120V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 16A continuous)- Attached NEMA L5-20P input with NEMA 5-20P plug adapter, 12 ft. / 3.6m input cable- 1U horizontal rackmount form factor- 16 switched NEMA 5-15/20R outlets (8 front / 8 rear)- Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis- Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets- Network interface provides PDU control and data regarding input voltage and total output load level in amps- Digital display continuously reports total output load level in amps- Supports user-specified alarm notification thresholds- In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats- Mounting ears are reversible for front or rear facing rackmount installation- Included cord retention brackets- TAA Compliant Version Available - Order Tripp Lite PDUMH20NETAA
Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. - Switched 30A 208/240V PDU, 2U horizontal rackmount format - Reports voltage, frequency & load level via ethernet interface - Visual current meter, Reversible housing - NEMA L6-30P input plug with attached 12 ft. / 3.6m line cord - 16 switched C13 outlets with cord retention brackets - Temperature, humidity and contact closure monitoring options - Rackmount PDU - Installable 2U mounting brackets - 30A 208/240V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 24A continuous) - Attached L6-30P 208/240V single phase input, 12 ft. / 3.6m input cord - 2U horizontal rackmount form factor - 16 switched c13 outlets - Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis - Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets - Network interface provides PDU control and data regarding input voltage and total output load level in amps - Digital display continuously reports output load in amps in 3 segments (load bank 1, load bank 2, total) - Supports user-specified alarm notification thresholds - In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors - DHCP/Manual configuration support - 10/100 Mbps auto-sensing - Real-time clock backup maintains the time of day and date even if the PDU is unpowered - Tiered access privileges allow an administrator and a guest to login via web browser - Alert notifications via email or SNMP traps offer immediate event notification - Firmware upgrade ability supports future product enhancements - Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols - Fully compatible with FREE PowerAlert Network Management System / NMS Software - 2U horizontal rack installation supported in 2 or 4 post racks with included mounting brackets - Mounting brackets support wall-mount and under-counter installation in many applications - Included cord retention brackets
Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.- 30A 120V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 24A continuous)- Attached L5-30P 120V single phase input, 10 ft. / 3m input cord- 2U horizontal rackmount form factor- 16 NEMA 5-15/20R switched outlets- Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis- Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets- Network interface provides PDU control and data regarding input voltage and total output load level in amps- Digital display continuously reports output load in amps in 3 segments (load bank 1, load bank 2, total)- Supports user-specified alarm notification thresholds- In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats- Mounting ears are reversible for front or rear facing rackmount installation- Included cord retention brackets- TAA Compliant Version Available - Order Tripp Lite PDUMH30NETAA
The PDUMH32HVAT 7.7kW Single-Phase 200-240V Local Metered Automatic Transfer Switch / ATS PDU provides power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 2U of space in EIA-standard 19-inch racks and features 18 outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker.Dual three-meter input cords with IEC 309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 200-240V power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.Multifunction digital display with LED indicators reports output current, voltage and kW loading information.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA