"Tripp Lite PDUV20-72. PDU types: Basic, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 36 AC outlet(s), AC outlet types: NEMA 5–15, NEMA 5–20R, Power plug: NEMA L5-20P. Cable length: 179.9"" (4.57 m). Nominal input voltage: 100 - 127 V, Maximum current: 20 A, AC input frequency: 50 - 60 Hz. Width: 1.5"" (38.1 mm), Depth: 1.64"" (41.7 mm), Height: 72.5"" (1840.7 mm)"
FeaturesSingle-Phase 208/230V PDU Distributes Network-Grade Power to Multiple LoadsThis basic PDU is an ideal no-frills unit for networking, telecom, security, audio/video and soundreinforcement applications. Recommended for small to mid-sized data centers, computer rooms and network closets, the PDUV20HVL6-72 features 32 C13 and six C19 outlets for connecting equipment. A 10-foot cord with NEMA L6-20P input plug connects to your facility’s AC power source, generator or protected UPS system to distribute power to connected loads. The switchless design helps prevent an accidental shutdown, which could lead to costly downtime.Versatile Installation Options Give You Plenty of ChoicesThe 63.75-inch all-metal housing supports 0U vertical mounting in an EIA-standard 19-inch rack using the included toolless mounting buttons or the included mounting clips and hardware. You may also use the clips to secure the PDU to a wall, counter or other flat, secure surface. Included C20 and C14 plug-lock inserts attach to the connected components’ plugs to keep them connected and the devices continuously powered.
Three-Phase 208/120V PDU Distributes Network-Grade Power to Multiple LoadsThis basic PDU is an ideal no-frills unit for networking, telecom, security, audio/video and sound reinforcement applications. Recommended for small to mid-sized data centers, computer rooms and network closets, the PDU3V6L2130 features 36 C13 (208V), six C19 (208V) and six NEMA 5-15/20R (120V) outlets in three breakered load banks for connecting equipment. A six-foot cord with L21-30P input plug connects to your facility’s AC power source, generator or protected UPS system to distribute power to connected loads.Up-to-Date Safety Features Protect Your Vital EquipmentThe switchless design helps prevent an accidental shutdown, which could lead to costly downtime. Three 20A circuit breakers, one per output phase, protect connected components from dangerous overloads.Easy to Install Vertically in an EIA-Standard 19 in. RackThe 70-inch 0U PDU’s all-metal housing mounts vertically using the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. Cable retention brackets keep power cords organized and your rack free of clutter.TAA-Compliant for GSA Schedule PurchasesThe PDU3V6L2130 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
3-Phase 360-415V input / 208V-240V output PDU Distributes Network-Grade Power to Multiple LoadsThis basic rack PDU (rPDU) is an ideal no-frills unit for networking, telecom, security, audio/video and sound reinforcement applications. Recommended for small to mid-sized data centers, computer rooms and network closets, the PDU3XV6G20 features 36 C13 and six C19 (208-240V) outlets in three single-phase output load banks for connecting equipment. A six-foot (1.8-meter) cord with IEC 309 16/20A Red 360-415V (3P+N+E) 3-phase input plug connects to your facility’s AC power source, generator or protected UPS system to distribute power to connected loads.Easy to Install Vertically in an EIA-Standard 19 in. RackThe 70-inch 0U PDU’s all-metal housing mounts vertically using the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. Cable retention brackets keep power cords organized and your rack free of clutter. The PDU’s switchless design helps prevent an accidental shutdown, which could lead to costly downtime.
3-Phase 208V PDU Distributes Network-Grade Power to Multiple LoadsThis basic PDU is an ideal no-frills unit for networking, telecom, security, audio/video and sound reinforcement applications. Recommended for small to mid-sized data centers, computer rooms and network closets, the PDU3V6H50 features 36 C13 (208V) and six C19 (208V) outlets in three breakered single-phase output load banks for connecting equipment. A six-foot (1.8 meters) cord with Hubbell 50A CS8365C (3P+E) 3-phase input plug connects to your facility’s AC power source, generator or protected UPS system to distribute power to connected loads.Easy to Install Vertically in an EIA-Standard 19 in. RackThe 70-inch 0U PDU’s all-metal housing mounts vertically using the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. Cable retention brackets keep power cords organized and your rack free of clutter. The PDU’s switchless design helps prevent an accidental shutdown, which could lead to costly downtime.TAA-Compliant for GSA Schedule PurchasesThe PDU3V6H50 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
3-Phase 120V PDU Distributes Network-Grade Power to Multiple LoadsThis basic PDU is an ideal no-frills unit for networking, telecom, security, audio/video and sound reinforcement applications. Recommended for small to mid-sized data centers, computer rooms and network closets, the PDU3V6L2120LV features 42 NEMA 5-15/20R outlets in three single-phase output load banks for connecting equipment. A six-foot (1.8-meter) cord with NEMA L21-20P 3-phase input plug connects to your facility’s AC power source, generator or protected UPS system to distribute power to connected loads.Easy to Install Vertically in an EIA-Standard 19 in. RackThe 70-inch 0U PDU’s all-metal housing mounts vertically using the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. Cable retention brackets keep power cords organized and your rack free of clutter. The PDU’s switchless design helps prevent an accidental shutdown, which could lead to costly downtime.TAA-Compliant for GSA Schedule PurchasesThe PDU3V6L2120LV is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Bypass PDU Recommended for Maintaining Continuous Power During UPS MaintenanceKeeping mission-critical data center equipment operating at its optimal level often means scheduledmaintenance. But what if you are unable to afford the costly downtime involved in powering down forregular upkeep? This 120V 20A single-phase hot-swap PDU works in conjunction with your UPS systemto keep everything running 24/7/365. It allows you to manually transfer connected equipment to utilitypower via the PDU’s bypass switch, permitting maintenance or equipment replacement with nointerruption of performance.Features Dual Inputs and a Manual Transfer Switch for Uninterrupted OperationThe PDUB201U includes separate UPS and utility input cables with NEMA 5-20P plugs. The manualtransfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace theUPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipmentconnected to the six NEMA 5-20R outlets will continue to operate without interruption.Optional ECO Switching Feature Enables Cost-Cutting Power SavingsBy enabling the ECO power saving feature, you can power off a single bank of five controlled 5-20Routlets all at once when the device connected to the master 5-20R outlet is powered off or goes into a lowpower consumption mode.Mounts into 1U of Rack Space or WallUse the included mounting hardware to install the PDUB201U’s all-metal housing into 1U of space in anEIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
Bypass PDU Recommended for Maintaining Continuous Power During UPS MaintenanceKeeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200–250V 10A single-phase hot-swap rack PDU (rPDU) works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU’s bypass switch, permitting maintenance or equipment replacement with no interruption of performance.Features Dual Inputs and a Manual Transfer Switch for Uninterrupted OperationThe PDUBHV101U features two C14 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C13-to-C14 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the six C13 outlets will continue to operate without interruption.Optional ECO Switching Feature Enables Cost-Cutting Power SavingsBy enabling the ECO power saving feature, you can power off a single bank of five controlled C13 outlets all at once when the device connected to the master C13 outlet is powered off or goes into a low-power consumption mode. Mounts into 1U of Rack Space or on a WallUse the included mounting hardware to install the PDUBHV101U’s all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
Bypass PDU Recommended for Maintaining Continuous Power During UPS MaintenanceKeeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200–250V 16A single-phase hot-swap rack PDU (rPDU) works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU’s bypass switch, permitting maintenance or equipment replacement with no interruption of performance.Features Dual Inputs and a Manual Transfer Switch for Uninterrupted OperationThe PDUBHV201U features two C20 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C19-to-C20 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the outlets will continue to operate without interruption.Optional ECO Switching Feature Enables Cost-Cutting Power SavingsBy enabling the ECO power saving feature, you can power off a single bank of four controlled C13 outlets all at once when the devices connected to the master C13 and C19 outlets are powered off or go into a low-power consumption mode. Mounts into 1U of Rack Space or on a WallUse the included mounting hardware to install the PDUBHV201U’s all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
Bypass PDU Recommended for Maintaining Continuous Power During UPS MaintenanceKeeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 220-240V 16A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU’s bypass switch, permitting maintenance or equipment replacement with no interruption of performance.Features Dual Inputs and a Manual Transfer Switch for Uninterrupted OperationThe PDUBHV20D features two C20 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the four Schuko outlets will continue to operate without interruption.Optional ECO Switching Feature Enables Cost-Cutting Power SavingsBy enabling the ECO power saving feature, you can power off a single bank of three controlled Schuko outlets all at once when the device connected to the master Schuko outlet is powered off or goes into a low-power consumption mode. Mounts into 2U of Rack Space or on a WallUse the included mounting hardware to install the PDUBHV20D’s all-metal housing inside a 19-inch rack. Because the rack PDU (rPDU) 56.1-millimeter height is larger than 1U in an EIA-standard rack, you will need to mount the unit into 2U of space. You may also use the mounting brackets to secure the PDU to a wall.