Tripp Lite single phase Metered PDU / Power Distribution Units offer real-time local reporting of load level in amps via built-in digital display. Enables visual monitoring of PDU load levels to prevent overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.- 30A single phase 120V Metered Power Distribution Unit / PDU (Agency de-rated to 24A continuous)- Set of two lighted meters report PDU output current in amps for each 12 outlet load bank- Attached NEMA L5-30P 30A 120V input plug with 10ft / 3m line cord- 0U vertical rackmount format installs using no rack spaces- 24 NEMA 5-15/20R output receptacles- Outlets are arranged in two 12 outlet load banks, each with separate 20A breaker and current metering- Toolless installation supported in button-mount compatible equipment racks- Bolt-down installation brackets support installation in other racks and additional surfaces- Cord retention brackets keep vital equipment plugs connected
The PDUMV30HVNETLX 5/5.8kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 24 switched outlets (20 C13 and 4 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. LEDs indicate each outlet’s on/off power status. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.A digital ammeter allows you to monitor each bank’s load in real time to ensure it remains well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.Distributes Network-Grade Single-Phase Power- 5/5.8kW 208/240V 30A switched PDU with single-phase input/output- Recommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network components- NEMA L6-30P plug with 10 ft. cord connects to compatible AC power source- Firmware upgrades support future product enhancements24 Switched Outlets Distribute AC Power- 20 C13 and 4 C19 outlets split into 2 separately breakered load banks- Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices- Plug-lock inserts prevent cables from becoming accidentally disconnectedDigital Ammeter- Reports load level on each bank and total PDU output- Supports IP-address self-ID- Rotates 180° for easy reading at either angleBuilt-In LX Platform Interface- Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities- No Java requiredBroad Communications CompatibilitySupports HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTPSupports automatic and manual assignment of IP addressEasy 0U Installation in EIA-Standard 19 in. Racks- Mounts vertically using included toolless buttons or rack-mounting brackets- Included PDUMVROTATEBRKT allows mounting with rear-facing outletsTAA-Compliant- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Single-Phase 20A ATS PDU Distributes and Monitors Network-Grade Power in Real TimeThis metered PDU provides real-time local reporting of the total load level via its built-in digital current metering. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH20ATS features 16 NEMA 5-15/20R 120V outlets for connecting equipment. Dual 12-foot (3.7-meter) power cords with NEMA L5-20P inputs (two 5-20P adapters are included) connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.Switches from Primary to Secondary Power Source in MillisecondsAutomatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2–7 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.Digital Load Meter Helps Prevent Potentially Expensive OverloadsA digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.Mounts into 1U of Rack Space or on a WallUse the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.TAA-Compliant for GSA Schedule PurchasesThe PDUMH20ATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.- 30A 208/240V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 24A continuous)- Attached L6-30P 208/240V single phase input, 15 ft. / 4.6m input cord- 2U horizontal rackmount form factor- 14 switched outlets (8 C13, 6 C19)- Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis- Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets- Network interface provides PDU control and data regarding input voltage and total output load level in amps- Digital display continuously reports output load in amps in 3 segments (load bank 1, load bank 2, total)- Supports user-specified alarm notification thresholds- In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats- Mounting ears are reversible for front or rear facing rackmount installation- Included cord retention brackets- TAA Compliant Version Available - Order Tripp Lite PDUMH30HV19NTAA
The PDUMV20HVNETLX 3.3-3.7kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 24 switched outlets (20 C13 and 4 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-ft. (3.05 m) cord with NEMA L6-20P plug connects the PDU's C20 inlet to a compatible AC power source, generator or protected UPS.The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.A digital ammeter allows you to monitor each bank's load in real time to ensure it remains well below maximum capacity with no danger of overload. The vertical PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.
2.9kW vertical PDU distributes, monitors and manages single-phase power in an IT or industrial environment. Built-in network interface helps you remotely monitor load levels to prevent overloads that cause downtime.- 2.9kW 120V switched PDU- 24 individually controllable NEMA 5-15/20R outlets- Built-in LX Platform interface for 24/7 remote access- Digital ammeter for on-site load monitoring in real time- NEMA L5-30P input with 10 ft. AC power cord- 2-year limited warrantyPackage Includes- PDUMV30NETLX 2.9kW Single-Phase Switched PDU- Built-in LX Platform interface- Configuration cable- (24) Cable ties- (2) Cord retention brackets- Rack-mounting hardware- PDUMVROTATEBRKT mounting bracket accessory- Owner’s manualThe PDUMV30NETLX 2.9kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 24 switched NEMA 5-15/20R outlets with included cord retention brackets to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L5-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.A digital ammeter allows you to monitor each bank’s load in real time to ensure it remains well below maximum capacity with no danger of overload. The vertical PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.Distributes Network-Grade Single-Phase Power- 2.9kW 120V switched PDU- Recommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network components- NEMA L5-30P plug with 10 ft. cord connects to compatible AC power source- Firmware upgrades support future product enhancements24 Switched Outlets Distribute AC Power- 24 NEMA 5-15/20R outlets split into 2 separately breakered load banks- Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices- Cord retention brackets prevent cables from becoming accidentally disconnectedDigital Ammeter- Reports load level on each bank and total PDU output- Supports IP-address self-ID- Rotates 180° for easy reading at either angleBuilt-In LX Platform Interface - Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH- Supports 10/100 Mbps auto-sensing for communication with an Ethernet network- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities- No Java requiredBroad Communications Compatibility- Supports HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP- Supports automatic and manual assignment of IP addressEasy 0U Installation in EIA-Standard 19 in. Racks- Mounts vertically using included toolless buttons or rack-mounting brackets- Included PDUMVROTATEBRKT allows mounting with rear-facing outletsTAA-Compliant- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
The PDUMV20NETLX 1.9kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for IT and industrial applications, the vertical PDU features 24 switched NEMA 5-15/20R outlets with included cord retention brackets to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L5-20P plug connects the PDU to a compatible AC power source, generator or protected UPS.The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.A digital ammeter allows you to monitor the total load in real time to ensure it remains well below maximum capacity with no danger of overload. The vertical PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.
Tripp Lite single phase Metered PDU / Power Distribution Units offer real-time local reporting of load level in amps via built-in digital display. Enables visual monitoring of PDU load levels to prevent overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.
Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.- 120V 30A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 24A continuous)- Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord- Visual meter reports output amp and kW power consumption, plus input voltage- 2U horizontal rackmount form factor; 11.9 in. / 30.2 cm depth- 25 outlets (24 5-15/20R, 1 L5-30R)- Set of two 10 ft. / 3m NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections- ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable- Highly reliable solid-state switching enables fast 1-5 millisecond transfer between primary and secondary inputs- ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)- Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported- On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source- Front panel LEDs confirm power availability on both input lines- TAA Compliant Version Available - Order Tripp Lite PDUMH30ATAA
Single-Phase PDU Distributes and Monitors Network-Grade Power in Real TimeThis metered PDU provides real-time local reporting of the total load level via its built-in digital currentmetering. Ideal for network IT applications, small computer rooms and other equipment rack applications,the PDUMH20HVL66 features eight C13 and two C19 208/230V outlets for connecting equipment. Pluglock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.Digital Load Meter Helps Prevent Potentially Expensive OverloadsA digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensureload levels remain well below maximum capacity with no danger of overload that could lead to costlydowntime or damaged equipment. Maintaining proper load levels, even while adding new equipment, cankeep your TCO (total cost of ownership) low.Versatile Installation Options Give You Plenty of ChoicesThe reversible all-metal housing comes with mounting brackets for installation in 1U of space or 0Uvertical mounting in an EIA-standard 19-inch rack. You can also reorient the brackets for permanentmounting under a counter or on a wall with user-supplied hardware. The six-foot cord with NEMA L6-20Pinput plug connects the single-phase PDU to a protected UPS system, generator or mains input source forreliable multi-outlet power distribution.TAA-Compliant for GSA Schedule PurchasesThe PDUMH20HVL66 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligiblefor GSA (General Services Administration) Schedule and other federal procurement contracts.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA