"Tripp Lite ECO550UPS. UPS topology: Standby (Offline), Output power capacity: 0.55 kVA, Output power: 300 W. AC outlet types: NEMA 5–15R, Power plug: NEMA 5-15P, AC outlets quantity: 10 AC outlet(s). Battery voltage: 12 V, Typical backup time at full load: 1.2 min, Typical backup time at half load: 5 min. Form factor: Tower, Product color: Black, Housing material: Acrylonitrile butadiene styrene (ABS). Width: 4.33"" (110 mm), Depth: 7.28"" (184.9 mm), Height: 4.13"" (104.9 mm)"
Do you need to protect small- to medium-size servers, networking equipment and telecom systems against data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges? Tripp Lite’s SU1500XLCD SmartOnline® Tower UPS System is the solution! Featuring a 1500VA/1350W capacity and true on-line operation with pure sine wave output and zero transfer time to battery, it provides the highest level of power protection for mission-critical equipment. The SU1500XLCD’s large internal battery set supports connected equipment during blackouts, and runtime is expandable with optional external battery packs BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible), sold separately. The SU1500XLCD has 6 5-15R outlets, including 2 load banks of 3 outlets each that are individually controllable to reboot select equipment on demand or maximize battery runtime for mission-critical equipment. USB and DB9 communication ports support messaging of detailed UPS operational parameters and line power status. Included PowerAlert power management software supports an unlimited number of network UPS systems. The SU1500XLCD also accepts an optional SNMPWEBCARD accessory that enables the UPS to operate as a managed device on the network. It comes backed by a 2-year warranty and $250,000 of Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).- Ideal for Protection of Mission-Critical Equipment- True On-Line Operation with Pure Sine Wave Output and Zero Transfer Time- Individually Controllable Outlets- Reliable, Expandable Battery Backup- High Power Factor and Highly Efficient Operation Reduces BTU Output- AC Line and Tel/Ethernet Surge Suppression- EMI/RFI Line Noise Filtering- LCD Screen and Audible Alarm- USB/DB9 Ports, SNMP Capability and Included PowerAlert Software- Emergency Power Off (EPO) Capability- Peace of Mind
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 96% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and pre-installed SNMPWEBCARD network interface. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. Includes PowerAlert monitoring software and complete cabling. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules.- Tripp Lite SMART2200RMXLN line interactive 2U rack/tower UPS with 2200VA / 2.2kVA / 1920W capacity and extended runtime options- Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V- NEMA 5-20P input plug; 4 NEMA 5-15/20R and 4 5-15R output receptacles, Two independently switched output load banks- Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages- High 96% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions- Internal batteries offer 12 minutes at 50% load (960W) and 4.5 minutes at 100% load (1920W)- Extended runtime is available with optional BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible); Output is reduced to 1600 watts maximum with external battery packs- External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)- Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment- Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information- LCD interface also supports a number of advanced user setup and operating preferences- Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement- Built-in USB, RS-232 and pre-installed SNMPWEBCARD accessory- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X- Included PowerAlert UPS monitoring software; Built-in Emergency Power Off (EPO) interface with cable
"Tripp Lite ECO750UPS. UPS topology: Standby (Offline), Output power capacity: 0.75 kVA, Output power: 450 W. AC outlet types: NEMA 5–15R, Power plug: NEMA 5-15P, AC outlets quantity: 12 AC outlet(s). Typical backup time at full load: 2 min, Typical backup time at half load: 8.6 min. Form factor: Compact, Product color: Black, Housing material: Acrylonitrile butadiene styrene (ABS). Width: 5.12"" (130 mm), Depth: 12.2"" (309.9 mm), Height: 3.35"" (85.1 mm)"
"Tripp Lite OMNIVS1500LCD. UPS topology: Line-Interactive, Output power capacity: 1.44 kVA, Output power: 900 W. AC outlet types: NEMA 5–15R, Power plug: NEMA 5-15P, AC outlets quantity: 8 AC outlet(s). Typical backup time at full load: 2 min, Typical backup time at half load: 6 min. Form factor: Tower, Product color: Black, Housing material: Acrylonitrile butadiene styrene (ABS). Width: 5.5"" (139.7 mm), Depth: 15"" (381 mm), Height: 7.5"" (190.5 mm)"
"Tripp Lite SMART1500TSU. UPS topology: Line-Interactive, Output power capacity: 1.44 kVA, Output power: 1200 W. AC outlet types: NEMA 5–15R, Power plug: NEMA 5-15P, AC outlets quantity: 8 AC outlet(s). Typical backup time at full load: 1.5 min, Typical backup time at half load: 6 min. Form factor: Tower, Product color: Black, Housing material: Acrylonitrile butadiene styrene (ABS). Width: 5.5"" (139.7 mm), Depth: 15"" (381 mm), Height: 7.5"" (190.5 mm)"
1200VA/600W/120V Battery Backup for PCs, Home Theater or Digital SignageThis 120V UPS system with AVR provides reliable battery backup and AC power protection against blackouts, brownouts, overvoltages, surges and line noise that can destroy data or damage valuable electronics. It is ideal for protecting home office, media center or commerce components, including computers, routers, printers, HDTVs, Blu-ray players, game consoles, ATMs, security systems and digital signage equipment.Allows Time to Back Up Critical Files During a BlackoutBattery backup allows you to work through short power failures and gives you time to save files and shut down your system in case of a prolonged blackout. Backup time varies according to load, but this line-interactive UPS system can keep an energy-efficient desktop computer with small LCD monitor powered as long as 88 minutes. During normal operation, incoming utility power keeps the replaceable internal battery fully charged, so backup power is always available.Restarts Automatically After a Long OutageOnce utility power is restored after a prolonged outage, the UPS will automatically power up, even if the battery is expired and requires replacement. This battery independent restart feature eliminates the need to turn on the UPS manually after a blackout.Connects Your Equipment to 8 Protected NEMA 5-15R OutletsSix battery/surge-protected outlets provide battery backup and surge suppression for your computer, monitor and other critical equipment. Two additional surge-protected outlets provide surge suppression for peripherals that do not require battery backup, such as printers and speakers. A high >95% line mode efficiency rating reduces BTU emissions, energy consumption and, ultimately, your energy costs.Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage ConditionsAVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts and overvoltages. The OMNIVS1200LCD corrects brownouts as low as 89V and overvoltages as high as 145V back to nominal 120V power continuously, all while keeping the battery fully charged.Surge Suppression Protects AC and Tel/DSL/Ethernet LinesRated to 316 joules, this UPS system protects equipment connected to the outlets and RJ45 jacks (1 in/1 out) from the harmful effects of power surges that can occur over AC and telephone/network lines. The RJ45 jacks are not compatible with Power over Ethernet (PoE) applications.Combats Line Noise That Can Harm EquipmentEMI (electromagnetic interference) and RFI (radio frequency interference) are common causes of performance problems for electronics and can lead to incremental hardware damage, data corruption and audio/video transmission interruptions. The OMNIVS1200LCD filters out this disruptive line noise on the AC line to protect your equipment.Easy-to-Read LCD Touchscreen Reports Real-Time UPS and Power StatusThe LCD touchscreen offers five screens of UPS and site power information when the UPS is operating in either on-line or battery power mode. It displays vital voltage, load and battery data, as well as critical fault status. An audible alarm indicates low battery, excessive load or fault condition.HID-Compliant USB Port Allows for Unattended, Graceful ShutdownsThe USB port connects the OMNIVS1200LCD to a computer running Tripp Lite’s free downloadable PowerAlert® software, enabling a graceful system shutdown during a prolonged power failure. USB cable is included. This HID-compliant UPS also works with the built-in power management features of Windows, Mac and Linux operating systems.Tower Form Factor is Easy to Place in Your Workspace or Media CenterThe compact ABS housing fits easily on a desktop, shelf or anywhere else convenient to your workstation or home theater. The UPS has a 5-foot cord with a NEMA 5-15P plug for connection to a standard outlet. A built-in fan regulates the internal temperature to help prevent overheating.
Reliable LiFePO4 Battery Backup Offers Longer Life and Less Weight than Lead Acid BatteryThis Tripp Lite SmartPro® UPS lithium battery backup features a state-of-the-art lithium iron phosphate (LiFePO4) internal battery with longer life, more cycles and faster recharge. It more than doubles the service life of an equivalent lead acid battery, and offers up to three times more charge/discharge cycles. It recharges to 100% capacity in less than three hours, making the lithium UPS system an ideal backup in case of power outage. The LiFePO4 battery has 60% the weight of an equivalent lead acid battery, which reduces the overall UPS weight.120-Volt Battery Backup Keeps Equipment Operating Through Short Power FailuresThe SMART1000RM2UL provides up to 20 minutes (half load) and 8.3 minutes (full load) of battery backup, as well as AC power protection, for critical server, network and telecom equipment. In case of a prolonged blackout, the single-phase lithium UPS system gives you enough time to save important data and perform an orderly system shutdown.Automatic Voltage Regulation (AVR) Conserves Battery PowerWith an 800W capacity (1000VA), the line-interactive UPS system with automatic voltage regulation (AVR) maintains regulated 120V nominal output over an input range of 83V–147V without using battery power. Conserving power allows your LiFePO4 battery to last longer and maintain full capacity until needed.6 Outlets Protect Your Mission-Critical Rack EquipmentPlug your equipment into the six NEMA 5-15R outlets. Four outlets are split into two dual-outlet load banks that are switchable via network interface. These four outlets let you power connected equipment on and off remotely to reset or reboot connected equipment or to shed less significant loads to extend battery runtime for more critical equipment. All six outlets are protected by 570-joule network-grade surge protection to fight off damaging power surges and spikes.Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform BetterThis UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.High Efficiency Helps the Environment and Your Cash FlowOperating with a high 95% line-mode efficiency, the 1kVA UPS system can save BTU heat output and energy costs.Advanced Communications Ports Connect to Any Workstation or ServerUSB and DB9 ports (cables are included) enable data-saving unattended shutdown when used with Tripp Lite’s free downloadable PowerAlert® software. Capabilities include detailed monitoring of equipment load levels, self-test data and utility power condition. The Emergency Power Off (EPO) interface offers options for instantaneous power-off of the UPS system and connected equipment in case of fire or other facility emergency.Optional Network Management Cards Allow Detailed Monitoring of ConditionsThe SMART1000RM2UL is compatible with Tripp Lite network management cards, such as WEBCARDLX, for detailed monitoring of UPS and site power conditions.Multi-Function LCD and Audible Alarms Keep You InformedThe front-panel LCD information and configuration screen displays detailed UPS and site power status and operating data, as well as input and output voltage, operating mode, alarm function and additional options. An alarm sounds to warn you of power failure, low battery, overload, UPS fault and remote shutdown conditions. The LCD screen rotates for easy viewing in rack-mount or tower configuration.Versatile Installation OptionsHardware is included for mounting the Tripp Lite SmartPro UPS system in 2U of space in an EIA-standard 19-inch 4-post rack. Use the 2POSTRMKITWM (sold separately) for 2-post rack mounting or wall mounting or the UPSHDEARKIT (sold separately) for 2-post front-mount installation. Use the 2-9USTAND (sold separately) for mounting in an upright tower position. A 10-foot power cord with NEMA 5-15P plug connects the SMART1000RM2UL to a compatible AC power source.Typical Applications- Deliver regulated sine wave output to connected equipment in a network closet or small-business network- Protect point-of-sale and VoIP networks against power surges and spikes- Keep your server room operational during short power failures and allow time for safe shutdowns during longer blackouts- Back up servers, network storage devices, telecom hardware and other applications where long battery lifespan is critical- Provide high-level power protection with a low-maintenance designPackage Includes- SMART1000RM2UL SmartPro UPS, Lithium Battery Backup- USB cable- DB9 cable- EPO cable- Rack-mounting hardware- Owner’s manual
Protect Your Electronics with Voltage Regulation, Surge Suppression and Battery BackupLine-interactive UPS offers voltage regulation, surge suppression and battery backup support. It regulates brownouts as low as 170V and overvoltages as high as 280V back to usable levels without using battery power. All four IEC320 C13 UPS outlets offer battery backup, automatic voltage regulation and AC surge suppression. Three front panel LEDs and audible alarm combine to indicate off/on power status, line power availability, battery mode operation, low battery, overload, battery replacement and fault mode.Operate Your Connected Equipment During Short-Term OutagesThis UPS supports an entry-level PC consuming 60W continuous up to 32 minutes during power failure condition and a 50% load of 120W for 7 minutes. It also enables users to operate connected equipment during short-duration outages without interruption and shut down without data loss during longer outages. All the UPS C13 outlets receive battery backup.
Protect Your Electronics with Voltage Regulation, Surge Suppression and Battery BackupLine-interactive UPS offers voltage regulation, surge suppression and battery backup support. It regulates brownouts as low as 170V and overvoltages as high as 280V back to usable levels without using battery power. Both CEE 7/7 Schuko UPS outlets offer battery backup, automatic voltage regulation and AC surge suppression. Three front panel LEDs and audible alarm combine to indicate off/on power status, line power availability, battery mode operation, low battery, overload, battery replacement and fault mode.Operate Your Connected Equipment During Short-Term OutagesThis UPS supports an entry-level PC consuming 60W continuous up to 42 minutes during power failure condition and a 50% load of 180W for 6 minutes. It also enables users to operate connected equipment during short-duration outages without interruption and shut down without data loss during longer outages. All the UPS Schuko outlets receive battery backup.Two-Year Limited Warranty This UPS is backed by a two-year limited warranty, ensuring reliability and performance.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA