PFC Sinewave UPS Systems — Federal Trade Agreement Act (TAA) Compliant UPSThe CyberPower Federal Trade Agreements Act (TAA) compliant CP1500PFCLCDTAA PFC Sinewave™ UPS System with pure sine wave output and multifunction LCD safeguards mid- to high-end computer systems, servers and networking hardware that use conventional and Active Power Factor Correction (PFC) power supplies. Its Automatic Voltage Regulation (AVR) technology delivers clean and consistent AC power, protecting connected equipment and preventing costly business interruptions. Its patented GreenPower UPS™ advanced circuitry reduces UPS energy costs by up to 75% compared to competitive models.CyberPower’s PFC Sinewave UPS Systems with pure sine wave output solve the critical compatibility issues of non-sine wave UPS products working with computing systems using Active PFC power supplies (ENERGY STAR 5.0). With PC manufacturers adopting high-efficiency Active PFC power supplies—your equipment may be at risk. CyberPower’s innovative PFC Sinewave Series is an affordable solution that ensures equipment utilizing Active PFC power supplies do not unexpectedly shutdown or experience harmful stress when switching from AC power to UPS battery power.The CP1500PFCLCDTAA unit has a capacity of 1500VA/900Watts, ten (10) NEMA 5-15R receptacles and two (2) maintenance-free, user-replaceable 12V/8.5Ah batteries. The intelligent multi-function LCD panel displays real-time UPS vitals for ease of control. This unit offers connectivity via one (1) HID USB and one (1) DB9 serial ports. Protection for phone/network (RJ11/RJ45) and cable/coax (RG-6) is included. EMI/RFI filters increase the immunity of the load to noise disturbances. Two (2) 5Vdc USB 2.0 charging ports for portable devices such as mobile phones, MP3 players, and cameras.PowerPanel® Personal Edition UPS Management software automatically closes computer files and safely shuts down the system in case of a power outage. A Three-Year Warranty ensures that this UPS has passed our highest quality standards in design, assembly, material or workmanship and further protection is offered by a $500,000 Connected Equipment Guarantee.
Symmetra Power Module, 3200 Watts / 4000 VA,Input 200V, 208V / Output 100V, 120V, 200V, 208V.
The CSC16USB 16-Device USB Charging Station Cabinet provides fast charging, convenient syncing, secure storage and cord management for up to 16 iPad, Android, Surface and Kindle tablets, as well as mobile phones and other USB devices. It’s recommended for education, office, commercial, retail, industrial and healthcare environments.16 USB ports deliver the fastest charging supported by each device, up to 2.4A per port. A USB uplink port connects to a host computer for wired syncing, though the CSC16USB also supports wireless syncing and simultaneous syncing/charging (up to 1.5A per port during wired syncing).The cabinet promotes comprehensive device protection with steel construction and a black powder-coated finish for long-term durability. It locks with the included keys to help prevent device theft, damage or tampering. Flow-through ventilation protects against overheating, the specially coated shelves shelf helps prevent scratches and scuffs, and rubber grommets shield cords from damage.The cabinet also encourages clutter-reducing organization of devices and cabling. Charging cords store out of sight, and a toolless trim panel permits quick service access.The cabinet is easy to configure. The cabinet ships fully assembled and supports mounting to a wall, desk, table, counter or floor. The front doors open 180 degrees for improved device and service access. Rear-panel slots support optional wall-mount installation, and removable dividers accommodate thicker devices. You can also convert it the cabinet to a mobile cart with Tripp Lite’s optional CSHANDLEKIT2 (sold separately), and roll it where needed.
Tripp Lite's APS700HF Ultra-Compact DC-to-AC inverter with automatic line-to-battery transfer and integrated charging system serves as an extended run UPS, a standalone power source or an automotive inverter. Supplies up to 700 watts of continuous 120V AC power to 1 AC outlet from any 12V battery or automotive DC source. OverPower inverter output feature provides up to 120% of the continuous output for up to 5 seconds, and DoubleBoost inverter output feature delivers up to 200% of the continuous output for up to 2 seconds, providing the extra power needed to cold start heavy-duty tools and motorized equipment. When AC cable is connected to a live wall socket, commercial power passes through to connected equipment and the battery set is recharged via 3-stage, 6-amp charging system. In UPS mode, the APS system responds to blackouts and voltage fluctuations with a near instantaneous automatic transfer to battery-derived AC output. Includes a set of high current DC input terminals for simple installation (user supplies batteries and cabling - see owner's manual for recommendations). Passes sine wave utility or generator power during battery charging and UPS line power mode, plus efficient PWM sine wave AC output in inverter and UPS backup modes. Supports an unlimited amount of runtime with any number of user-supplied batteries connected.- 12V DC or 120V AC input; 120V AC output; 1 outlet- 700 watts continuous, 1050 watts OverPower and 1400 watts DoubleBoost inverter output- 6 amp rated, 3-stage, built-in battery charger- Auto Transfer Switching option for battery backup / UPS operation - with ISOBAR AC surge suppression- Ultra-compact, lightweight aluminum housing weighs only 4 lbs. / 1.8 kg
Trendnet 48VDC3000 power adapter/inverter Indoor 160 W Black
High availability, ruggedized power protection for shipboard and other transportation applications.
Seasonic SSP-650RS power supply unit 650 W 20-pin ATX ATX Silver
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 98% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support communications via USB, RS-232 and optional SNMPWEBCARD network interface. HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. Includes PowerAlert monitoring software and complete cabling. Switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules.- Tripp Lite SMART3000RM2U line interactive 2U rack/tower UPS with 3000VA / 3kVA capacity (1600W maximum load with external battery packs)- Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V- NEMA L5-30P input plug; 8 NEMA 5-15/20R and 1 L5-30R output receptacles, Two independently switchable output load banks- Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages- High 98% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions- Internal batteries offer 10 minutes at 50% load (1125W) and 3.5 minutes at 100% load (2250W)- Extended runtime is available with optional BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs (max output de-rates to 1600 watts with external batteries)- External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)- Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment- Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information- LCD interface also supports a number of advanced user setup and operating preferences- Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement- Built-in USB, RS-232 and optional SNMPWEBCARD accessory monitoring options- HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X- Included PowerAlert UPS monitoring software; Built-in Emergency Power Off (EPO) interface with cable
The PDUMH15HVAT 2–2.4kW Single-Phase 200–240V Local Metered Automatic Transfer Switch / ATS PDU enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features 10 C13 outlets.Dual 3.6-meter input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources in a nominal voltage range from 200–240V. Plug lock inserts prevent cords from accidental disconnection. The PDUMH15HVAT constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 2–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.Built-in slot supports the optional WEBCARDLX (sold separate), which turn the PDUMH15HVAT into a switched PDU by allowing remote access to the PDU for power monitoring, configuration, outlet control and notifications via web browser, SSH, telnet or SNMP. Digital ammeter monitors total output current. LEDs display outlet on/off status and input power status on primary and secondary inputs.
19 inch Rack-MountableSupplies redundant AC power to connected equipment. Two AC lines power the unit and if the primary AC power fails, the unit will automatically switch to the alternate power source.Quick Transfer RateTransfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.Wrap Around System Bypass(3) Breaker maintenance bypass panel to isolate the UPS from the critical loadMeets UL Requirements
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA