Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
APC Replacement Battery Cartridge #163
"APC NetShelter Rack PDU Advanced, Metered, 8.6kW, 3PH, 208V, 30A, L21-30P, 42 OutletAPC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2"" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected."
Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Integrates with InfraStruXure CentralAn IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkFlash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
"APC BK350. Output power capacity: 0.35 kVA, Output power: 210 W, Input frequency: 50/60 Hz. Typical backup time at full load: 4.7 min, Typical backup time at half load: 18.1 min, Battery recharge time: 8 h. Product color: Beige, Cable length: 70.9"" (1.8 m), Safety: UL/FCC/CE/C-Tick. Weight: 13.2 lbs (5.98 kg). Package weight: 14 lbs (6.36 kg)"
Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.High frequency designReduces or eliminates bulky transformers resulting in lighter units for ease of handling.Auto recognition of external batteriesUPS recognizes when external battery packs are attached and automatically adjusts runtime.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Outlet group controlTurn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).Load sheddingTurn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Multiple switched outlet groupsMultiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.Wide input voltage rangeDesigned for harsh electrical environments to save battery life.StruxureWare Central compatibleEnables centralized management via StruxureWare Central.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceHigh online efficiencyReduces utlility costs, generates less heat.LED IndicatorsProvide easy-to-read status of the unit and utility power conditions.Overload protectionSafeguards unit from damage by automatically turning it off in the event of a short circuit or overload.SmartSlotCustomize UPS capabilities with management cards.Cold-start capableProvides temporary battery power when the utility power is out.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedDisconnected battery notificationWarns when a battery is not available to provide backup power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltageregulation.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Audible alarmsProvides notification of changing utility power and UPS power conditionsUser-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)USB connectivityProvides management of the UPS via a USB port (not available on all models).Serial ConnectivityProvides management of the UPS via a serial port.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).Scalable runtimeAllows additional run time to be quickly added as needed.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Network manageableProvides remote power management of the UPS over the network.Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.Predicitive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.Sequenced network shutdown and rebootCustomize network shutdown and reboot sequence of connected servers and UPSs.
APC Maintenance Bypass Panels , Input: 120V , Input Connections: NEMA 5-20P , Cord Length: 8 feet ( 2.44 meters ) , Output: 120V , Output Connections: NEMA 5-15R,NEMA 5-20RQuick Transfer RateTransfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.Wrap Around System Bypass(3) Breaker maintenance bypass panel to isolate the UPS from the critical load
Reliable Backup Power and Protection for Your Valuable IT Equipment Protect your servers, switches, routers and networking devices while providing battery backup power with Smart-UPS SMT2200RM2UC with APC SmartConnect, the first cloud-enabled UPS for distributed IT. The service-free cloud monitoring feature is accessible from any internet-connected device, and maximizes the life and performance of your UPS by providing proactive advice and life-cycle recommendations so you can remotely monitor your power infrastructure from anywhere. An Overview of Smart-UPS and the SmartConnect App APC SmartConnect makes Smart-UPS more adaptable and easier to deploy than ever before, enabling you to view the status of your UPS through a secure web portal. Through this intuitive remote management interface, you’ll receive automatic notifications, firmware updates, and advanced support; providing you with added value – and more importantly – added peace of mind. Secure, remote monitoring Connected Smart-UPS support remote monitoring through a secure web portal, so you can always be up to date on the status of your power infrastructure. Proactive lifecycle alerts Maximize the life span of the UPS and protect your investment with proactive alerts for firmware upgrade, device maintenance, and warranty protection. Cloud enabled as standard Smart-UPS models with SmartConnect are cloud-enabled and have a built-in Ethernet port, making it easy and cost effective to monitor your UPS online. Simple to Use Interface Our simple web interface is designed to support both system administrators and non-tech users alike, with clear notifications in plain language.
"APC NetShelter Rack PDU Advanced, Metered, 5.0kW, 1PH, 208V, 30A, L6-30P, 40 OutletAPC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2"" wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.Maximum Outlet DensityAll models include 40, 42, or 48 outlets to accommodate even the highest density of devices, allow for more installation flexibility, and provide room for growth within the PDUs power capacity limits.Space SavingWith such high outlet counts and power capacity, NetShelter Advanced Rack PDUs are designed to maximize space with their single width form factor, often allowing for fewer PDUs to accommodate the same number of devices and power requirements.High Power CapacityModels now available to provide up to 34.6kW (derated to 80% capacity per National Electric Code (NEC) for North America) and up to 43.5kW for other countries to ensure support for most any density deployment and help minimize the number of PDUs needed to do so.APC Locking Power Cord CompatibleFree up space and secure power cords between rack-mount PDUs and attached IT equipment with this easy-to-use cord retention method. Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet; the ""locking"" feature is enabled when used with NetShelter Rack PDU Advanced to reduce the probability of accidental power cord disconnect.Circuit Breaker MonitoringAllows total load across each circuit breaker to be monitored for potential overload and can be configured to provide notification in the event of a circuit breaker trip.Alternating PhaseNetShelter Rack PDU Advanced incorporates an alternating phase design on 3 phase models whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU. This alternating phase layout facilitates better power cord management and more intuitive load balancing versus traditional PDU solutions where outlets are grouped by phase at the top, middle, and bottom of the PDU.60ºC (140ºF) Operating TemperatureRated and approved to operate up to 60C (140F) at full load, NetShelter Rack PDU Advanced ensures reliability and availability even in today's high density deployments.Power SharingRack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU. Network communication is uninterrupted, attached sensors still operate, and alarm traps remain available.Hydraulic Magnetic Circuit BreakersProvide increased availability by maintaining trip current over a wide temperature range.Live Swap Network Management CardThe Network Management Card (NMC) can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event.Color Coded OutletsTo simplify deployment, outlets on the PDUs are color coded by breaker on 1 phase models and color coded and/or labeled by breaker and input phase on 3 phase models.Environmental Sensor SupportTwo environmental sensor ports allow for optional sensors (sold separately) to be connected. Sensors available within the NetSelter Rack PDU Advanced portfolio include temperature, temperature/humidity, temperature (3 sensors)/humidity, rope leak detection, and a door contact switch. Also available is an expansion hub to allow connection of up to three sensors providing the ability to manage six separate sensors from one rack PDU. Sensor availability expected late 2022.Wide Offer BreadthMetered, Switched, and Metered-by-Outlet with Switching functionality are available across all power configurations ranging from 5kW up to 34.6kW to meet the need for most deployments.Network CascadingConnect and manage up to 32 PDUs from a single IP address to simplify and speed PDU deployment while reducing networking costs associated with having a dedicated network connection for each PDU.US Based ManufacturingUS based manufacturing enables better product availability and ability to offer configure-to-order (CTO) products (optional and subject to pricing and leadtimes) including different cord lengths, plug types, and PDU chassis color.Dual RatedFor data center deployments across multiple regions, select models are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.Flexible PDU MountingWith pre-installed mounting pegs, NetShelter Rack PDU Advanced can be quickly installed in the toolless mounting holes of the rear accessory channel in a NetShelter SX and many 3rd party cabinets. Mounting pegs can be repositioned to the side of the PDU to rotate the orientation of the outlets 90 degrees and face the back of the cabinet for better clearance from device chassis or mounting rails.4-in-1 Combination OutletsOffering unparalleled flexibility, 4-in-1 combination outlets which can be used as either C13 or C19 enable a single PDU outlet layout to support various rack layouts and configurations. In addition, the same 4-in-1 combination outlets also serve as high temperature C15 and C21 outlets for devices with C16 and C22 power cords. With 4-in-1 combination outlets redeployment of a PDU with new rack layout or configuration is easy and straightforward, often preventing the need to remove and discard a PDU upon IT refresh.Color LCD DisplayNetShelter Rack PDU Advanced provides a rich color LCD display for local management and control at the rack.Dual Network PortsA second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy.1% Metering AccuracyProviding the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring.Gigabit Ethernet ConnectivityProvides Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center.Network Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web and SNMP. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time."
Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.High frequency designReduces or eliminates bulky transformers resulting in lighter units for ease of handling.Auto recognition of external batteriesUPS recognizes when external battery packs are attached and automatically adjusts runtime.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Outlet group controlTurn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).Sequenced shutdown and restartConfigure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).Load sheddingTurn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Multiple switched outlet groupsMultiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.Wide input voltage rangeDesigned for harsh electrical environments to save battery life.StruxureWare Central compatibleEnables centralized management via StruxureWare Central.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceHigh online efficiency Reduces utlility costs, generates less heat.LED IndicatorsProvide easy-to-read status of the unit and utility power conditions.Overload protectionSafeguards unit from damage by automatically turning it off in the event of a short circuit or overload.SmartSlotCustomize UPS capabilities with management cards.Cold-start capableProvides temporary battery power when the utility power is out.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedDisconnected battery notificationWarns when a battery is not available to provide backup power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Audible alarmsProvides notification of changing utility power and UPS conditionsUser-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)USB connectivityProvides management of the UPS via a USB port (not available on all models).Serial ConnectivityProvides management of the UPS via a serial port.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery.Scalable runtimeAllows additional run time to be quickly added as needed.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Network manageableProvides remote management of the UPS over the network.Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.Predicitive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.