APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
ConveniencePrepaid postage to a nearby recycling partner (availability varies by country)Insures that almost 100% of the old battery is recycled, protecting the environment.Fully assembled for easy hot-swap installationAPC RBCs are safe, reliable and contain a minimum number of connections saving valuable time. Because APC RBCs are hot-swappable, no network downtime is required in order to install them.Re-usable packaging with clear instructions on how to properly dispose of spent batteries.Convenient, easy and green.Guaranteed UPS compatibilityTested and approved to restore the performance of your APC UPS. Maintains UPS safety certifications (UL, VDE, CSA) and lifetime equipment protection policy (as applicable).Long battery lifeDesigned by APC by Schneider Electric exclusively for APC UPS's for complete compatibility with the intelligent battery management system.
Cold-start capableProvides temporary battery power when the utility power is out.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.High online efficiencyReduces utility costs, generates less heat.LCD Status DisplayProvides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.SmartConnectInnovative, easy to use remote monitoring feature that provides automatic notifications, firmware updates, and advanced support services.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Save time with easy and convenient remote accessibilityNetwork manageable via serial, USB or optional ethernet. Includes Powerchute® Business Edition Software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities.Avoids costly power problems by keeping your IT equipment and data safe and availableNetwork grade power conditioning protects from damaging surges and disruptive noise. Solid state automatic voltage regulation boosts low input voltage up to 30% and trims high voltage up to 12% without battery operation. Reliable battery back-up capacity to power through outages or gracefully shutdown systemsPeace of mind that comes with full equipment compatibility and reliability of a leaderProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.Smarter productivity with ability to tailor to your specific application needsIntuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery managementPatented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.Resettable circuit breakersEnables a quick recovery from overload events.Predictive failure notification.Provides early-warning fault analysis ensuring proactive component replacement.User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedBattery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceAutomatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Disconnected battery notificationWarns when a battery is not available to provide backup power.Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).Network manageableProvides remote power management of the UPS over the network.Serial connectivityProvides management of the UPS via a serial port.USB connectivityProvides management of the UPS via a USB port (not available on all models).Audible alarmsProvides notification of changing utility power and UPS conditions.LED status indicatorsQuickly understand unit and power status with visual indicators.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Cold-start capableProvides temporary battery power when the utility power is out.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.High online efficiencyReduces utlility costs, generates less heat.Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Single switched outlet groupSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.SmartSlotCustomize UPS capabilities with management cards.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).Disconnected battery notificationWarns when a battery is not available to provide backup power.Audible alarmsActively let you know if the unit is on battery, if the battery is low or if there is an overload condition.LED status indicatorsQuickly understand unit and power status with visual indicators.Serial connectivityProvides management of the UPS via a serial port.USB connectivityProvides management of the UPS via a USB port (not available on all models).Disconnected battery notificationWarns when a battery is not available to provide backup power.Network manageableProvides remote power management of the UPS over the network.Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedBattery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenancePredictive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.Resettable circuit breakersEnables a quick recovery from overload events.Avoids costly power problems by keeping your IT equipment and data safe and availableNetwork grade power conditioning protects from damaging surges and disruptive noise. Solid state automatic voltage regulation boosts low input voltage up to 30% and trims high voltage up to 12% without battery operation. Reliable battery back-up capacity to power through outages or gracefully shutdown systemsLow operating and maintenance costs with high efficiency, proven reliability and intelligent battery managementPatented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.Save time with easy and convenient remote accessibilityNetwork manageable via serial, USB or optional ethernet. Includes Powerchute Business Edition Software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities.Peace of mind that comes with full equipment compatibility and reliability of a leaderProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.Smarter productivity with ability to tailor to your specific application needsIntuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Intelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
"APC RBC55. Battery technology: Lead acid, Product color: Black, Battery capacity: 816 Wh. Weight: 53.6 lbs (24.3 kg), Width: 5.59"" (142 mm), Height: 6.81"" (173 mm)"
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
High density, double-conversion on-line power protection with scalable runtimeIncludes : CD with software, Documentation CD, Installation guide, Removable support feet, USB cable, Warranty card.
APC Smart-UPS 3000VA LCD RM 2U 120V with Network CardAdjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.Audible alarmsProvides notification of changing utility power and UPS power conditionsAutomatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceBoost and Trim Automatic Voltage Regulation (AVR)Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.Disconnected battery notificationWarns when a battery is not available to provide backup power.Energy meterProvides actual kilowatt hours of usage for energy conscious users.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedIntelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.LED IndicatorsProvide easy-to-read status of the unit and utility power conditions.Network manageableProvides remote power management of the UPS over the network.Outlet group controlTurn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.Sequenced network shutdown and rebootCustomize network shutdown and reboot sequence of connected servers and UPSs.Serial connectivityUse any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.Single switched outlet groupSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.USB connectivityProvides management of the UPS via a USB port (not available on all models).ManageabilityLED status indicatorsQuickly understand unit and power status with visual indicators.Serial connectivityProvides management of the UPS via a serial port.USB connectivityProvides management of the UPS via a USB port (not available on all models).Disconnected battery notificationWarns when a battery is not available to provide backup power.Audible alarmsActively let you know if the unit is on battery, if the battery is low or if there is an overload condition.Network manageableProvides remote power management of the UPS over the network.Marketing FeaturesPeace of mind that comes with full equipment compatibility and reliability of a leaderProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.Avoids costly power problems by keeping your IT equipment and data safe and availableNetwork grade power conditioning protects from damaging surges and disruptive noise. Solid state automatic voltage regulation boosts low input voltage up to 30% and trims high voltage up to 12% without battery operation. Reliable battery back-up capacity to power through outages or gracefully shutdown systemsSave time with easy and convenient remote accessibilityNetwork manageable via serial, USB or optional ethernet. Includes Powerchute® Business Edition Software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities.Smarter productivity with ability to tailor to your specific application needsIntuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery managementPatented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.AvailabilityBoost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Disconnected battery notificationWarns when a battery is not available to provide backup power.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.AdaptabilityAdjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.ServiceabilityResettable circuit breakersEnables a quick recovery from overload events.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceUser-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedPredictive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.SafetySafety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Integrates with InfraStruXure CentralAn IT-ready, scalable monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkFlash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA